Low-voltage electrical maintenance and fault response

We respond to failures and maintain panels, breakers, starters, protections and connections. We diagnose, replace components, source spare parts and integrate new equipment into your installation.

The service

What it involves

Most low-voltage electrical failures start with something that could have been spotted earlier: a loose connection that heats up, a worn contact or a breaker no one has tested in years. Scheduled maintenance finds those points before they cause a shutdown.

When the failure has already happened, what matters is finding the real cause, not just replacing the part. We diagnose, correct and leave you in writing what should be addressed next.

When is it needed?

  • You have an urgent failure that needs attention right now.
  • Your panels have not been maintained in a long time.
  • There are loose or damaged connections, a burning smell or noises in a panel.
  • You need to connect new equipment to your installation.
  • You want an annual electrical maintenance program.
Scope

What it includes

The final scope is defined with you, based on your installation and what you need to solve.

Inspection and diagnosis

Review of panels, connections and protections to find the real cause of the failure or the risk points.

Cleaning and re-torquing

Panel cleaning and re-torquing of connections.

Component replacement

Replacement of damaged or discontinued components, with spare parts sourced by us.

Report

What was found, what was corrected, the components replaced and what should be addressed next.

Required information

What we need to serve you

The basics are enough to quote. If you are missing some data, don't stop: we gather it on site as part of the service.

To quote

Check what you already have. When you submit, WhatsApp opens with your request ready; there you can attach files and photos.

Prefer email? Send this request by email →

We respond to your request within 24 hours · You can also call +52 81 8396 0695 or +52 81 1485 3613.

To carry out the work

Requested once the service is confirmed. We help you gather it.

  • Single-line diagram of the areas to be serviced.
  • History of previous failures and maintenance, if you have it.
  • Spare parts available in your storeroom.
  • Work permit and your plant's lockout/tagout procedure.
  • Plant contact person during the service.

Your information is treated as confidential and is used only for your project.

On-site measurement

Studies with measurements at your plant

We measure directly at your facility and deliver interpreted results with clear recommendations.

Electrical diagnostics of motors and equipment

We check voltage, current, imbalance and harmonics on the equipment supply while it runs.

Useful for: motors that overheat or trip, drives with repeated faults and checking equipment before accepting it.

Harmonics assessment

We measure voltage and current distortion, harmonic by harmonic, at the points you are concerned about.

Useful for: transformers or cables that overheat, failing capacitors and loads with drives or rectifiers.

How we work

How the service is performed

1

Diagnosis

We review your installation and the failure or the condition of the equipment.

2

Proposal

We define what gets corrected, what gets replaced and in which window.

3

Execution

We source the spare parts and carry out the work.

4

Report

We deliver the report with photos and recommendations.

Frequently asked questions

What people ask us most

Do you handle urgent failures?

Yes. Send us a description and photos of the failure on WhatsApp; we respond within 24 business hours.

How often should maintenance be done?

As a reference, an annual review; the frequency is adjusted to the condition and criticality of each piece of equipment.

Do you source spare parts?

Yes. We source the components and, if they are discontinued, propose an equivalent replacement.

Can you connect new equipment to my installation?

Yes. We verify that the panel and protections have capacity for the new load and make the connection during the agreed window.