Protection coordination: only what should trip, trips

We review and adjust your protections so that, in the event of a fault, only the breaker closest to the problem opens. That way a fault in one motor doesn't shut down the whole plant, and downtime is reduced.

The study

What is protection coordination?

In a well-coordinated installation, each protective device has a job: the motor protection protects the motor, the feeder protection protects the feeder, and the main breaker acts only if the others did not. When the settings are not coordinated, a small fault trips the main breaker and all production is lost.

The protection coordination study plots the time-current curves of relays, breakers and fuses along each path, from the service entrance to the loads, and defines the settings that achieve selectivity while still protecting the equipment. It also provides the clearing times used in the Arc Flash study.

When is it needed?

  • The main breaker trips due to faults in a single piece of equipment.
  • Your breakers still have their factory settings and have never been reviewed.
  • You have medium-voltage relays without a settings study.
  • There were expansions, a new transformer or breaker replacements.
  • You are going to perform the Arc Flash study: trip times determine the incident energy.
  • You have recurring shutdowns with no clear cause.
Scope

What it includes

The final scope is defined with you, based on your installation and what you need to solve.

Protection inventory

Relays, breakers with trip units, molded-case breakers and fuses, with their current settings.

Time-current curves

Plots per path showing how each device acts relative to the ones upstream and downstream.

Settings table

Recommended pickup, time delay, instantaneous and ground fault values for each device.

Equipment protection

Verification against the damage curves of transformers and cables, and motor starting.

Implementation (optional)

Application of the settings on site and verification, during the agreed shutdown window.

Unresolvable points

Equipment that cannot be coordinated with what is installed, and the recommended alternative.

Required information

What we need to perform the study

The basics are enough to quote. If you are missing some data, don't stop: we gather it on site as part of the service.

To quote

Check what you already have. When you submit, WhatsApp opens with your request ready; there you can attach files and photos.

Prefer email? Send this request by email →

We respond to your request within 24 hours · You can also call +52 81 8396 0695 or +52 81 1485 3613.

To perform the study

Requested once the service is confirmed. We help you gather it.

  • Current short circuit study, or the data needed to perform it.
  • Brand, model and current settings of relays and breakers (photos of the trip units are useful).
  • Type, rating and curve of the installed fuses.
  • Transformer nameplate data.
  • Power and starting method of the main motors.
  • CFE protection settings at the connection point, which the coordination must respect.
  • Recent trip history, if you have it.

Your information is treated as confidential and is used only for your project.

How we work

How the study is performed

1

Information review

We receive the single-line diagram, the short circuit study and the current settings.

2

Site survey

We verify the protections and their actual settings on site.

3

Selectivity study

We plot the curves and define the recommended settings.

4

Handover and implementation

We deliver the report and, if you wish, apply the settings.

Frequently asked questions

What people ask us most

What is selectivity?

It is the condition in which, during a fault, only the protective device closest to the fault point operates and the rest of the installation keeps running.

Why is the short circuit study needed?

Protection curves are compared against the fault currents at each point. Without knowing those currents, reliable settings cannot be defined.

Can the settings be applied without shutting down?

It depends on the device. Some settings require de-energizing or working on the equipment; we schedule them with you in a shutdown window and under your safety procedures.

What if my breakers don't allow adjustment?

The study identifies it and proposes the alternative: replacing the device, using fuses with a different curve or changing the configuration.